Related Experiment Video
Updated: Dec 18, 2025

Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
Are high fresh gas flow rates necessary during the wash-in period in low-flow anesthesia?
Mahmut Arslan1, Gökçe Gişi1, Gözen Öksüz1
1Department of Anesthesiology and Reanimation, School of Medicine, Kahramanmaras Sutcu Imam University, Kahramanmaras, Turkey.
Abstract:
In low-flow anesthesia (LFA), there is a wash-in period in which usually high fresh gas flow (FGF) rates are used to achieve the required initial concentration of anesthetic agent in the alveoli. The aim of this study was to compare the efficiency, safety and the consumption of desflurane in LFA using constant FGF (1 L/min) and conventional LFA using high FGF (4 L/min) during the wash-in period. Eighty patients, who were scheduled for elective surgery under general anesthesia with endotracheal intubation, were enrolled in the study. Wash-in was accomplished with 1 L/min FGF (50% O2, 50% air) and 18% desflurane in group 1; and by 4 L/min FGF (50% O2, 50% air) and 6% desflurane in group 2. Throughout the surgery, the vaporizer was adjusted to maintain 0.6 to 0.8 minimum alveolar concentration (MAC). The time required to reach 0.7 MAC was shorter in group 1 (160 seconds [135-181] vs 288 seconds [240-500], P < .001). In 6 patients in group 1 and 13 in group 2, vaporizer settings were adjusted to maintain 0.6 to 0.8 MAC (P = .048). Desflurane consumption in the first hour and total desflurane consumption were higher in group 2 (P < .001 and P = .012, respectively). The efficiency of anesthesia in both the first hour and in total was higher in group 1 (P < .001). It is safe, more efficient, and economical to use 1 L/min FGF during the wash-in period in LFA.
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Inhalational Anesthetics: Overview
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...