Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Equipments Used to Measure Body Temperature01:13

Equipments Used to Measure Body Temperature

1.6K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.6K
Assessing Body Temperature - Oral01:14

Assessing Body Temperature - Oral

1.2K
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
1.2K
Assessing Body Temperature - Rectal01:27

Assessing Body Temperature - Rectal

9.9K
Rectal temperature measurement is considered the most precise method for assessing core body temperature and typically registers higher than oral temperature. For adults, the rectal thermometer should be inserted 1 to 1.5 inches into the rectum to obtain the most accurate reading.
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
9.9K
Temperature Measurement Sites01:14

Temperature Measurement Sites

2.9K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
2.9K
Assessing Body Temperature - Tympanic membrane01:14

Assessing Body Temperature - Tympanic membrane

1.0K
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
1.0K
Assessing Body Temperature - Axilla01:14

Assessing Body Temperature - Axilla

1.0K
Procedural Guide for Assessing Axillary Body Temperature using a Digital Thermometer:
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
1.0K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Non-destructive monitoring of cyenopyrafen residues on strawberry via 280 nm UV-excited fluorescence of co-formulated organic solvents.

Food chemistry: X·2026
Same author

A multiplex microarray lateral flow immunoassay device for simultaneous determination of five mycotoxins in rice.

NPJ science of food·2024
Same author

Perceptions of the 2D short animated videos for literacy against chronic diseases among adults with diabetes and/or hypertension: a qualitative study in primary care clinics.

BMC primary care·2024
Same author

Addressing Water Contamination and Associated Health Issues through Community-Based Interventions: A Case Study in Khon Kaen Province.

International journal of environmental research and public health·2024
Same author

Infrared-based temperature measurement in three dimensions.

Applied optics·2024
Same author

Potent environmental-friendly virucidal medical textiles against coronavirus to combat infections during the COVID-19 pandemic.

Journal of industrial textiles·2024

Related Experiment Video

Updated: Dec 18, 2025

In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography
07:03

In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography

Published on: May 30, 2020

4.7K

Temperature-compensated infrared-based low-cost mobile platform module for mass human temperature screening.

Armote Somboonkaew, Sirajit Vuttivong, Panintorn Prempree

    Applied Optics
    |June 17, 2020
    PubMed
    Summary
    This summary is machine-generated.

    This study introduces a low-cost mobile platform for rapid human temperature screening in public areas. The system achieves high accuracy in detecting elevated temperatures using combined visible and thermal imaging.

    More Related Videos

    Thermal Imaging to Study Stress Non-invasively in Unrestrained Birds
    10:07

    Thermal Imaging to Study Stress Non-invasively in Unrestrained Birds

    Published on: November 6, 2015

    13.9K
    Fabrication of Microscope Stage for Vertical Observation with Temperature Control Function
    06:21

    Fabrication of Microscope Stage for Vertical Observation with Temperature Control Function

    Published on: July 31, 2019

    7.8K

    Related Experiment Videos

    Last Updated: Dec 18, 2025

    In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography
    07:03

    In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography

    Published on: May 30, 2020

    4.7K
    Thermal Imaging to Study Stress Non-invasively in Unrestrained Birds
    10:07

    Thermal Imaging to Study Stress Non-invasively in Unrestrained Birds

    Published on: November 6, 2015

    13.9K
    Fabrication of Microscope Stage for Vertical Observation with Temperature Control Function
    06:21

    Fabrication of Microscope Stage for Vertical Observation with Temperature Control Function

    Published on: July 31, 2019

    7.8K

    Area of Science:

    • Engineering
    • Computer Science
    • Biomedical Engineering

    Background:

    • The need for rapid, non-contact human temperature screening in public spaces is critical for public health.
    • Existing methods may lack efficiency or accuracy in crowded environments.

    Purpose of the Study:

    • To develop a low-cost, mobile platform for fast and accurate human temperature screening.
    • To integrate visible and thermal imaging for improved face detection and temperature analysis.

    Main Methods:

    • A mobile platform module, µTherm, was developed using a FLIR ONE camera for visible and thermal imaging.
    • Face detection in visible images was used to identify regions of interest for thermal temperature analysis.
    • Internal temperature compensation and external reference temperature were employed to enhance accuracy.

    Main Results:

    • The µTherm system can simultaneously determine the temperatures of nine people at 8 frames/second.
    • Field tests with 1,170 people demonstrated 100% sensitivity, 92.6% specificity, and 92.7% accuracy.
    • The system proved effective for rapid temperature screening in a real-world setting.

    Conclusions:

    • The developed mobile platform offers a promising solution for efficient and accurate mass human temperature screening.
    • The combined visible and thermal imaging approach with compensation techniques enhances screening reliability.
    • This technology has significant potential for public health surveillance and early detection of fever.