Related Experiment Video
Updated: Dec 18, 2025

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Study of hot stress dynamic IR thermography for detecting surface cancerous tissue
Uddip Kashyap1, Subhasish Sarkar2, Sandip K Saha1
1Department of Mechanical Engineering, Indian Institute of Technology Bombay, Mumbai, India.
Abstract:
The early diagnosis of cancer at any location of the human body can help in enhancing the survival rate and in reducing the cost of the treatment. Among the several techniques, the conventional infra-red (IR) thermography suffers from several limitations, including higher patient discomfort and longer time for tumour detection based on the temperature difference between tumour and adjacent healthy tissues. Hence, in this work, a novel non-invasive hot stress dynamic IR thermography system is proposed to detect surface tumour without severe discomfort to the patient. The system is designed to detect the surface tumour under 3 min within a temperature range of 42 and 37 °C. A two-dimensional numerical model based on the bio-heat transfer of tissue consists of cancerous and healthy cells is developed and validated to analysis the thermal contrast arises due to the presence of cancerous and healthy cells while cooling naturally. A light source is introduced with appropriate intensity to achieve a suitable temperature contrast. Moreover, the effects of natural convective heat loss from the tissue to the ambient and the scanning speed of IR Thermography on the tissue are investigated. A temperature difference of about 1.5 °C is found after cooling of tissues for 140 s, which can be detected using a thermographic camera. Finally, a sensitivity study is conducted to access the importance of the individual parameter over the final temperature field. The results predict the blood perfusion rate as the most significant parameter that significantly influences the temperature distribution in the considered domain.
Related Concept Videos
Thermal Stress
Absorption of Radiation
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...

