Related Experiment Video
Updated: Dec 18, 2025

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Simultaneous Determination of Chlorinated and Brominated Acetic Acids in Various Environmental Water Matrixes by
Bassam Lajin1, Walter Goessler1
1Institute of Chemistry-Analytical Chemistry for Health and Environment, University of Graz, Universitaetsplatz 1, 8010 Graz, Austria.
Abstract:
The halogenated acetic acids (HAAs) are generally considered as environmental contaminants and are suspected to pose a major public health concern. The inductively coupled plasma mass spectrometry (ICPMS) has been improved by coupling with the tandem mass spectrometry technology (ICPMS/MS), enabling ultratrace determination of heteroatoms. There have been few reports about the determination of chlorine-containing analytes by high-performance liquid chromatography (HPLC)-ICPMS/MS but none about utilizing this technique for the speciation analysis of organic halogenated compounds in environmental matrixes. We report a rapid method for the simultaneous determination of up to nine chlorinated and brominated acetic acids by HPLC-ICPMS/MS in Austrian surface, ground, and tap water. The chromatographic separation of the main five regulated haloacetic acids (so-called HAA5: chloroacetic acid, dichloroacetic acid, trichloroacetic acid, bromoacetic acid, and dibromoacetic acid) could be achieved in <6 min with limits of detection of 1.4-1.6 μg Cl L-1 and 0.8-1.5 μg Br L-1 for the chlorinated and brominated acetic acids, respectively. The method was validated through recovery experiments at four concentration levels (10-500 μg L-1) as well as by analyzing the U.S. Environmental Protection Agency (EPA) 552.2 CRM (certified reference material) in pure water and in three different water matrixes (tap, river, and groundwater), and thereby validated for repeatability (RSD% 1-10%), accuracy (±1.0-15%), and linearity (r2 = 0.9996-0.9999). The method fulfills the regulatory concentration limits by the EPA for HAA5 [maximum contaminant level (MCL) 60 μg L-1] and the limits currently being reviewed by the European Union for HAA9 (80 μg L-1) and demonstrates the advantages of HPLC-ICPMS/MS for the analysis of environmental water samples for halogen-tagged contaminants.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
05:20Avocado Sample Preparation Using the QuEChERS Method with Ammonium Formate for Pesticide Analysis
Published on: December 8, 2023
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences