Abstract:
Plate theory and adsorption theory are the main tools available for understanding chromatographic experiments. Both theories predict a Gaussian distribution of solute molecules within the tubular system. However, Gaussian concentration distributions are observed predominantly at slow linear flow rates, while asymmetric concentration distributions are observed at the linear flow rates most used in chromatography. Allegedly, this asymmetry originates from an inhomogeneous distribution of grain sizes in the column and column overload. However, it is an experimental fact that the distribution of chemicals within an injected volume of solute changes as a function of time, while the response is measured simultaneously. Accordingly, the obtained signal cannot be compared to the theory before some type of time-based deconvolution of the data has been performed. Adjustments to high-performance liquid chromatography data were thus proposed through empirical equations that describe the relevant time values, peak height, peak area, and parameters of the van Deemter equation. It was proposed that the transfer of solute from the front to the rear part of the pulse during laminar open-ended flow occurs at rate that depends on the linear flow rate, and to a lesser extent, on properties of the response function.
Related Concept Videos
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Chromatographic Methods: Terminology
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Electrophoresis: Overview
There...