Related Experiment Video
Updated: Dec 18, 2025

An Open-Source Normothermic Perfusion System Designed for Research Scientists
Published on: July 18, 2025
Validation study of perfusion parameter in hypervascular hepatocellular carcinoma and focal nodular hyperplasia using
Kazuhiro Saito1, Joseph Ledsam2, Steven Sourbron2
1Department of Radiology, Tokyo Medical University, Shinjuku-ku, Tokyo, Japan.
Background:
Dynamic susceptibility contrast MR imaging (DSC-MRI) offers direct evaluation of neo-vascularity. Ferucarbotran does not accumulate in the interstitial space, instead remaining in the intravascular space during early phase imaging. We investigate tracer kinetic analysis with DSC-MRI with ferucarbotran and single level CT during hepatic arteriography (SL-CTHA) in assessment of hypervascular hepatocellular lesions and evaluate the usefulness of DSC-MRI with ferucarbotran.
Methods:
Six patients having hypervascular hepatocellular carcinoma (HCC) and 3 patients having focal nodular hyperplasia (FNH) were included in the study. SL-CTHA was performed with the infusion of 3 mL of contrast media at a rate of 1 mL/s and scanned at a rate of 0.8 second per rotation. DSC-MRI was acquired with the echo-planar method at 1.5T system. A total dose of 1.4 mL (0.5 mol Fe/L) of ferucarbotran was used. Ferucarbotran was injected at a rate of 2 mL/s with 40 mL of physiological saline. Imaging was obtained at a temporal resolution of 1.2 or 0.46 seconds in 5 and 4 patients, respectively. For both CT and MRI modalities, a model-free analysis method was used to derive region of interest-based perfusion parameters. Plasma flow, distribution volume (DV) of contrast agent and estimated mean transit time (EMTT) were estimated.
Results:
A strong correlation was obtained with plasma flow (r=0.8231, P=0.0064) between DSC-MRI and SL-CTHA. No significant correlation was obtained for DV and EMTT between DSC-MRI and SL-CTHA. All perfusion parameters showed no significant difference between SL-CTHA and DSC-MRI in FNH. On the other hand, in HCC, DV and EMTT showed significant differences (P=0.046 and 0.046), and plasma flow showed no significant difference between DSC-MRI and SL-CTHA.
Conclusions:
This pilot study demonstrates the possibility of quantitative analysis of liver tumor using superparamagnetic iron oxide (SPIO)-based agent and highlights the potential for SPIO-based agent in more precisely assessing the perfusion characteristic of hypervascular liver tumors than by using extracellular contrast media.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Magnetic Resonance Imaging

