Correlation study in the measurements of oblique passive ductions and cyclorotation
E Hernández García1, M R Gómez de Liaño Sánchez1
1Hospital Clínico San Carlos, Madrid, España.
Purpose:
To evaluate intraoserver and inteobserver repeatability of the "exaggerated forced duction test" or "oblique traction test" and the "excyclo and incyclo passive rotation test" or "cyclorotation traction test".
Methods:
44 eyes of 22 patients were evaluated under deep general anesthesia. Passive duction was tested on supraduction and infraduction by the "exaggerated duction test". The limitation on movement was graduated from 0 to - 4. Passive cyclorotation test was evaluated with retropulsion of the globe until the first resistance is noted. We used the Mendez ring and blue dots marked on the limbus to measure the amount of cyclorotation. The results obtained of excyclo and incyclorotation were recorded. All measurements were made in duplicate for each of the two observers.
Results:
The intraclass correlation of the "oblique traction test" coefficient between the two observers was for the IO was 0,738 (95% confidence interval, 0,62-0,83) and 0,910 for the superior oblique (SO) (95% confidence interval, 0,85-0,94). The "cyclorotation traction test" intraclass correlation coefficient of the between the two observers was 0,827 (95% confidence interval, 0,74-0,89) for exclycloduction and 0,792 (95% confidence interval, 0,67-0,85) for inclycloduction. The percentage of patients within 5° of rotation interobserver was 84,1% for excyclorotation and 81,8% for inclyclorotation. Both tests had better correlation on the intraobserver than interobserver evaluation.
Conclusions:
Evaluation of the "oblique traction test" and "cyclorotation traction test" had moderate to good correlation between the two observers and good to excellent on the intraobserver evaluation.
More Related Videos
Related Concept Videos
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Correlation of Experimental Data
For example, a spherical particle moving through a viscous fluid experiences drag. Dimensional analysis shows that the drag force depends on the particle's diameter, velocity,...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Coriolis Force
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...