Related Experiment Video
Updated: Dec 18, 2025

Confocal Imaging of Neuropeptide Y-pHluorin: A Technique to Visualize Insulin Granule Exocytosis in Intact Murine and Human Islets
Published on: September 13, 2017
Pitfalls in the Detection of Insulinomas With Glucagon-Like Peptide-1 Receptor Imaging
Kwadwo Antwi1, Matthias Hepprich2, Natasha A Müller3
1From the Clinic of Radiology and Nuclear Medicine.
Purpose:
Physiological pancreaticoduodenal uptake of radiolabeled exendin-4 in Brunner glands of the proximal duodenum is the most common pitfall for false interpretation of glucagon-like peptide-1 receptor (GLP-1R) imaging. The aim of this study was to analyze the pancreaticoduodenal uptake in GLP-1R PET/CT and SPECT/CT images and to identify additional potential reading pitfalls in patients with suspected insulinoma.
Methods:
A post hoc analysis of a prospective study, including 52 consecutive patients, was performed. All patients underwent 1 Ga-exendin-4 PET/CT and 2 In-exendin-4 SPECT/CT scans (4 and 72 hours postinjection) in a randomized crossover order. Three board-certified nuclear medicine physicians read all scans independently. They were unaware of other results. Reference standard was surgery with histopathological confirmation of an insulinoma/nesidioblastosis and normalization of blood glucose levels after surgery.
Results:
There were no false-positive readings. However, there were a number of false-negative PET/CT and SPECT/CT readings, respectively: (1) due to false interpretation of uptake in the pancreaticoduodenal region (falsely interpreted as physiological uptake in Brunner glands instead of an insulinoma in 0.6% vs 9.0%), (2) due to ectopic insulinoma (0% vs 2.6%), (3) due to small insulinoma (1.9% vs 5.1%), (4) due to insulinoma overlap with kidneys (1.9% vs 4.5%), and (5) due to nesidioblastosis (0.6% and 1.9%). Pitfalls were identified in all GLP-1R PET/CT and SPECT/CT scans.
Conclusions:
Peripancreatic uptake, small size of an insulinoma, insulinoma overlap with kidneys, and presence of nesidioblastosis are potential pitfalls in GLP-1R imaging, which can lead to false reading results.
Related Concept Videos
Glucagon-like Receptor Agonists
GLP-1, when administered in high doses intravenously, triggers insulin secretion, inhibits glucagon release, slows gastric emptying, reduces food intake, and restores normal insulin secretion. However, its rapid inactivation by...
Hypoglycemia and Glucagon
Glucose Homeostasis: Pancreatic Islets and Insulin Secretion
Insulin and C-peptide are...
Insulin: The Receptor and Signaling Pathways

