Related Experiment Video
Updated: Dec 18, 2025

Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
Isobaric Tandem Mass Tag Multiplexed Post-Translational Modification Quantitation of Biopharmaceuticals by Targeted
Yuan Mao1, Andrew Kleinberg1, Ning Li1
1Analytical Chemistry, Regeneron Pharmaceuticals, Inc., 777 Old Saw Mill River Road, Tarrytown, New York 10591, United States.
Abstract:
Peptide mapping coupled with liquid chromatography-mass spectrometry (LC-MS) has become an essential analytical technique to quantify the quality attributes (e.g., post-translational modifications [PTMs]) of monoclonal antibodies (mAbs) during drug development. However, the traditional label-free approach for relative quantitation of PTMs requires a great amount of instrument time for LC-MS data acquisition of individual digested samples, which limits the efficiency of peptide mapping when there is an increasing demand for protein characterization. Here, we developed a tandem mass tag (TMT)-based approach in combination with targeted mass spectrometry for multiplexed site-specific PTM quantitation of monoclonal antibodies to overcome this limitation. This approach enables the simultaneous quantitation of quality attributes (e.g., PTMs) for multiple samples in a single LC-MS run. By adjusting higher-energy collision dissociation (HCD) normalized collisional energies (NCEs) from 35 to 90, different types of PTMs were quantified with percentages comparable to those obtained using the conventional approach. The TMT overlabeling on the off-target amino acid residues serine, threonine, and tyrosine was observed to pose a challenge for this targeted MS/MS-based PTM quantitation. However, we inhibited this off-target overlabeling by adding a small-molecule additive during the TMT labeling as a decoy reagent to deplete the excess amount of TMT reagent. The PTM quantitative performance of this approach demonstrated high sensitivity and reproducibility of PTM quantitation with levels as low as 1.0%. Finally, this approach has been utilized to quantify the PTMs for forced degradation samples, comparability samples, and trisulfide standards of monoclonal antibodies.
More Related Videos
Related Concept Videos
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Resolution Mass Spectrometry (HRMS)
MALDI-TOF Mass Spectrometry