Related Experiment Video
Updated: Dec 17, 2025

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Routine Stent Flushing with Heparinized Saline during Distal Filter-Protected Carotid Artery Stenting: A Technical
Afroditi Maria E Mitka1, Christos D Karkos1, Konstantinos O Papazoglou1
1Vascular Unit, 5th Department of Surgery, Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Introduction:
Delayed embolization after filter-protected carotid artery stenting (CAS) may occur because of the protrusion and release of loose atherosclerotic plaque fragments through the stent cells.
Methods And Results:
We describe a technical modification to the standard filter-protected CAS by introducing an extra step, that of washing away the luminal stent surface debris with heparinized saline while the filter is still in place. Aided by the guiding catheter, flushing heparinized saline under manual pressure against the stent will force all loose fragments distally in the internal carotid artery to be captured by the overlying filter.
Conclusions:
Stent washout with heparinized saline before filter retrieval during filter-protected CAS may potentially increase debris capture and reduce delayed embolization.
More Related Videos
12:30Vascular Gene Transfer from Metallic Stent Surfaces Using Adenoviral Vectors Tethered through Hydrolysable Cross-linkers
Published on: August 12, 2014
06:53A Rat Carotid Artery Pressure-Controlled Segmental Balloon Injury with Periadventitial Therapeutic Application
Published on: July 9, 2020
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Cardiac Catheterization IV: Nursing Management