Related Experiment Video
Updated: Dec 17, 2025

The Fabrication and Operation of a Continuous Flow, Micro-Electroporation System with Permeabilization Detection
Published on: January 7, 2022
Microampere Electric Current Causes Bacterial Membrane Damage and Two-Way Leakage in a Short Period of Time
Venkata Rao Krishnamurthi1, Ariel Rogers1, Janet Peifer1
1Department of Physics, University of Arkansas, Fayetteville, Arkansas, USA.
Abstract:
Physical agents, such as low electric voltage and current, have recently gained attention for antimicrobial treatment due to their bactericidal capability. Although microampere electric current was shown to suppress the growth of bacteria, it remains unclear to what extent the microampere current damaged the bacterial membrane. Here, we investigated the membrane damage and two-way leakage caused by microampere electric current (≤100 μA) with a short exposure time (30 min). Based on MitoTracker staining, propidium iodide staining, filtration assays, and quantitative single-molecule localization microscopy, we observed significant membrane damage, which allowed two-way leakage of ions, small molecules, and proteins. This study paves the way to new development of antimicrobial applications for ultralow electric voltage and current.IMPORTANCE Although electric voltage and current have been studied for a long time in terms of their ability to suppress the growth of bacteria and to kill bacteria, increasing interest has been aroused more recently due to the prevalence of antibiotic resistance of microbes in past decades. Toward understanding the antimicrobial mechanism of low electric voltage and current, previous studies showed that treating bacteria with milliampere electric currents (≥5 mA) for ≥72 h led to significant damage of the bacterial membrane, which likely resulted in leakage of cellular contents and influx of toxic substances through the damaged membrane. However, it remains unclear to what extent membrane damage and two-way (i.e., inward and outward) leakage are caused by lower (i.e., microampere) electric current in a shorter time frame. In this work, we set out to answer this question. We observed that the membrane damage was caused by microampere electric current in half an hour, which allowed two-way leakage of ions, small molecules, and proteins.
Insights
Microampere electric current causes significant bacterial membrane damage and two-way leakage of cellular components within 30 minutes. This finding supports the development of novel antimicrobial strategies using low electric voltage and current.
Area of Science:
- Microbiology
- Biophysics
- Biotechnology
Background:
- Antibiotic resistance necessitates novel antimicrobial strategies.
- Low electric voltage and current show potential for bactericidal effects.
- Previous research focused on milliampere currents, leaving microampere effects unclear.
Purpose of the Study:
- To investigate bacterial membrane damage caused by microampere electric current.
- To determine the extent of two-way leakage (inward and outward) across the bacterial membrane.
- To explore the antimicrobial potential of ultralow electric voltage and current.
Main Methods:
- MitoTracker staining to assess membrane integrity.
- Propidium iodide staining to detect membrane permeabilization.
- Filtration assays and quantitative single-molecule localization microscopy to analyze leakage.
Main Results:
- Microampere electric current (≤100 μA) induced significant bacterial membrane damage within 30 minutes.
- Observed two-way leakage of ions, small molecules, and proteins through the damaged membrane.
- Demonstrated a clear link between microampere current exposure and membrane disruption.
Conclusions:
- Microampere electric current is effective in damaging bacterial membranes.
- This damage facilitates both influx and efflux of cellular substances.
- The findings support the advancement of antimicrobial applications utilizing ultralow electric currents.