Related Experiment Video
Updated: Dec 17, 2025

In Vivo Mouse Model of Spinal Implant Infection
Published on: June 23, 2020
Bacterial Colonisation of Suction Cannulas in Orthopaedic Surgery
E González Edery1, F Monclou Garzón1, J Reatiga2
1Departamento de Ortopedia y Traumatología, Clínica Valle Salud, Cali, Valle del Cauca, Colombia.
Introduction:
Osteoarticular infections represent a major complication in orthopaedic surgery. The aim is to identify the percentage of suction cannulas colonised and to determine the relationship between the time they are used in surgery and the colonisation of these cannulas.
Materials And Methods:
Descriptive and prospective study that analysed 546 suction cannulas used in clean orthopaedic surgery in a trauma centre, between November 2017 and March 2018. The distal end of the cannula was cultured to determine the colonisation rate.
Results:
7.3% of the cultured cannulas were positive for pathogens, the most frequent being Staphylococcus epidermidis at 27.5%. In addition, an association was found between colonisation and the length of time the cannula was used. The possibility of colonisation of cannulas used for between 60minutes or more, is greater than those used for less than 60minutes; between 60 and 90minutes the possibility is twice as high OR= 2.2 (CI:95% 1.1 - 4.1) and in cannulas used for more than 90minutes it is 8 times higher OR= 8.49 (CI:95% 1.77 - 40.86).
Conclusions:
The colonisation rate of cannulas is lower than reported in the literature. The longer the cannula is used in surgery increases the risk of their colonisation. Follow-up studies are being considered to determine whether suction cannula colonisation is associated with increased postoperative infection.
More Related Videos
04:37Author Spotlight: Advancing Research on Candida albicans Biofilm-Associated Prosthetic Joint Infections
Published on: February 2, 2024
18:40Combined In vivo Optical and µCT Imaging to Monitor Infection, Inflammation, and Bone Anatomy in an Orthopaedic Implant Infection in Mice
Published on: October 16, 2014
Related Concept Videos
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required
Bacterial Signaling
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Suctioning II: Procedure