Related Experiment Video
Updated: Dec 17, 2025

Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Left ventricular myocardial deformation pattern, mechanical dispersion, and their relation with electrocardiogram
Mario Verdugo-Marchese1, Stefano Coiro2,3,4, Christine Selton-Suty5
1Département coeur-vaisseaux, Centre Hospitalier Universitaire Vaudois (CHUV), Rue du Bugnon 46, 1011 Lausanne, Switzerland.
Aims:
Mechanical alterations in patients with electrical conduction abnormalities are reported to have prognostic value in patients with left ventricular asynchrony or long QT syndrome beyond electrocardiogram (ECG) variables. Whether conduction and repolarization patterns derived from ECG are associated with speckle tracking echocardiography parameters in subjects without overt cardiac disease is yet to be investigated. To report ranges of longitudinal deformation according to conduction and repolarization values in a population-based cohort.
Methods And Results:
One thousand, one hundred, and forty subjects (48.6 ± 14.0 years, 47.7% men) enrolled in the fourth visit of the STANISLAS cohort (Lorraine, France) were studied. Echocardiography strain was performed in all subjects. RR, PR, QRS, and QT intervals were retrieved from digitalized 12-lead ECG. Echocardiographic data were stratified according to quartiles of QRS and QTc duration values. Full-wall global longitudinal strain (GLS) was -21.1 ± 2.5% with a mechanical dispersion (MD) value of 34 ± 12 ms. Absolute GLS value was lower in the longest QRS quartile and shortest QTc quartile (both P < 0.001). Time-to-peak of strain was not significantly different according to QRS duration although significantly higher in patients with higher QTc (P < 0.001). MD was significantly greater in patients with longer QTc (32 ± 12 ms for QTc < 396 ms vs. 36 ± 12 ms for QTc > 421 ms; P = 0.002).
Conclusion:
Longer QTc is related to increased MD and better longitudinal strain values. In a population-based setting, QRS is not associated with MD, suggesting that echocardiography-based dyssynchrony does not largely overlap with ECG-based dyssynchrony.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
09:15Displacement Analysis of Myocardial Mechanical Deformation DIAMOND Reveals Segmental Heterogeneity of Cardiac Function in Embryonic Zebrafish
Published on: February 6, 2020