Related Experiment Video
Updated: Dec 17, 2025

Author Spotlight: Advancing Rapid Detection of Respiratory Pathogens Using Microfluidic Chip
Published on: March 29, 2024
Next Day Legionella PCR: a highly reliable negative screen for Legionella in the built environment
Katherine E Fisher1, Leah P Wickenberg1, Lesley F Leonidas2
1Phigenics Research and Innovation Team, Nevada Center for Applied Research, Reno, NV, USA
Abstract:
The opportunistic, waterborne pathogen Legionella caused 9,933 cases of Legionnaires' disease in 2018 in the United States (CDC.gov). The incidence of Legionnaires' disease can be reduced by maintaining clean building water systems through water management programs (WMPs). WMPs often include validation testing to confirm the control of bacteria, but the traditional culture method for enumerating Legionella requires 10-14 days to obtain results. A rapid DNA extraction developed by Phigenics and a real-time PCR negative screen for the genus Legionella provided results the day after sampling. This study evaluated the Next Day Legionella PCR (Phigenics, LLC) compared with the traditional culture method (ISO 11731) on 11,125 building water samples for approximately 1 year. Two DNA extraction methods (Methods 1 and 2) were compared. The negative predictive value (NPV) of the Next Day Legionella PCR in comparison to traditional culture for Method 1 was 99.95%, 99.92%, 99.85%, and 99.17% at >10, >2, >1, and >0.1 CFU/ml limits of detection, respectively. The improved DNA extraction (Method 2) increased the NPV to 100% and 99.88% at >1 and >0.1 CFU/ml, respectively. These results demonstrate the reliability of the genus-level Legionella PCR negative screen to predict culture-negative water samples.