Related Experiment Video
Updated: Dec 17, 2025

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
A Voltage-Sensitive Ultrasound Enhancing Agent for Myocardial Perfusion Imaging in a Rat Model
Michael Cimorelli1, Michael A Flynn1, Brett Angel2
1Chemical and Biological Engineering, Drexel University, Philadelphia, Pennsylvania, USA.
Abstract:
Echocardiographers with specialized expertise sometimes perform myocardial perfusion imaging using U.S. Food and Drug Administration-approved microbubbles in an off-label capacity, correlating microbubble replenishment in the near field with blood flow through the myocardium. This study reports the in vivo clinical feasibility of a voltage-sensitive ultrasound enhancing agent (UEA) for myocardial perfusion imaging. Four UEAs were injected into Sprague-Dawley rats while ultrasound images were collected to quantify brightness in the left ventricular (LV) cavity, septal wall, and posterior wall in systole and diastole. Formulation IV, a phase change agent nested within a negatively charged phospholipid bilayer, increased the tissue-to-cavity ratio in both systole and diastole in the septal wall, 6 dB, and in the posterior wall, 5 dB, while leaving the LV cavity at baseline. This outcome improves the signal of the myocardium relative to the LV cavity and shows promise as a myocardial perfusion UEA.