Related Experiment Video
Updated: Dec 17, 2025

Large-Scale SARS-CoV-2 Testing Utilizing Saliva and Transposition Sample Pooling
Published on: June 23, 2022
Suboptimal Biological Sampling as a Probable Cause of False-Negative COVID-19 Diagnostic Test Results
Natalie N Kinloch1,2, Gordon Ritchie3,4, Chanson J Brumme2,5
1Faculty of Health Sciences, Simon Fraser University, Burnaby, Canada.
Abstract:
False-negative severe acute respiratory syndrome coronavirus 2 test results can negatively impact the clinical and public health response to coronavirus disease 2019 (COVID-19). We used droplet digital polymerase chain reaction (ddPCR) to demonstrate that human DNA levels, a stable molecular marker of sampling quality, were significantly lower in samples from 40 confirmed or suspected COVID-19 cases that yielded negative diagnostic test results (ie, suspected false-negative test results) compared with a representative pool of 87 specimens submitted for COVID-19 testing. Our results support suboptimal biological sampling as a contributor to false-negative COVID-19 test results and underscore the importance of proper training and technique in the collection of nasopharyngeal specimens.
More Related Videos
07:13Swabbing the Urban Environment - A Pipeline for Sampling and Detection of SARS-CoV-2 From Environmental Reservoirs
Published on: April 9, 2021
11:11Efficient SARS-CoV-2 Quantitative Reverse Transcriptase PCR Saliva Diagnostic Strategy utilizing Open-Source Pipetting Robots
Published on: February 11, 2022
Related Concept Videos
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Controls in Experiments