Related Experiment Video
Updated: Dec 17, 2025

Author Spotlight: Advancing Hepatic Fibrosis Diagnosis Using Magnetic Resonance Elastography and AI
Published on: July 21, 2023
MR elastography of the liver: comparison of three measurement methods
1Department of Radiology, Hanyang University School of Medicine, Hanyang University Medical Center, Seoul, South Korea.
Aim:
To analyse the inter- and intra-observer agreement of liver stiffness value (LSV) using three methods with 3 T magnetic resonance elastography (MRE) and to investigate factors related to LSV difference.
Materials And Methods:
This retrospective study included 147 patients. Two independent observers measured the LSV using three region of interest (ROI) methods: (1) circular ROI with a radius of 1 cm in the right lobe, (2) largest ROI possible, and (3) average value considering the measurement area. The agreement and factors related to difference of LSV were investigated.
Results:
The intraclass correlation coefficients were excellent at 0.982-0.997 in all methods. The differences between observers for method 1 were significantly larger than those of method 2 or method 3 (p<0.001). The Child-Pugh classification was only related to LSV difference (p<0.001).
Conclusion:
Methods 2 and 3 were significantly more reliable than method 1. The Child-Pugh classification was only related to difference of LSV.