Related Experiment Video
Updated: Dec 17, 2025

A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Experimental central composite design-based dispersive liquid-liquid microextraction for HPLC-DAD determination of
Reza Mohammadzaheri1,2, Mehdi Ansari Dogaheh3, Maryam Kazemipour1,2
1Department of Chemistry, Science and Research Branch, Islamic Azad University, Kerman, Iran.
Abstract:
Diazinon poisoning is an important issue in occupational, clinical, and forensic toxicology. While sensitive and specific enough to analyse diazinon in biological samples, current methods are time-consuming and too expensive for routine analysis. The aim of this study was therefore to design and validate a simple dispersive liquid-liquid microextraction (DLLME) for the preparation of urine samples to be analysed for diazinon with high performance liquid chromatography with diode-array detector (HPLC-DAD) to establish diazinon exposure and poisoning. To do that, we first identified critical parameters (type and volume of extraction and disperser solvents, pH, surfactant, and salt concentrations) in preliminary experiments and then used central composite design to determine the best experimental conditions for DLLME-HPLC-DAD. For DLLME they were 800 µL of methanol (disperser solvent) and 310 µL of toluene (extraction solvent) injected to the urine sample rapidly via a syringe. The sample was injected into a HPLC-DAD (C18 column, 250×4.6 mm, 5 μm), and the mobile phase was a mixture of acetonitrile and buffer (63:37 v/v, pH 3.2; flow rate: 1 mL/ min). Standard calibration curves for diazinon were linear with the concentration range of 0.5-4 µg/mL, yielding a regression equation Y=0.254X+0.006 with a correlation coefficient of 0.993. The limit of detection and limit of quantification for diazinon were 0.15 µg/mL and 0.45 µg/mL, respectively. The proposed method was accurate, precise, sensitive, and linear over a wide range of diazinon concentrations in urine samples. This method can be employed for diazinon analysis in routine clinical and forensic toxicology settings.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Types of Detectors

