Stability of complete blood count parameters depends on the storage temperature, storage time, transport position and

Huseyin Kayadibi1, Ismail Aytac Acar1, Samet Cam1

  • 1Department of Medical Biochemistry, Hitit University School of Medicine, Corum, Turkey.

Purpose: To evaluate stability of CBC parameters in samples containing K3-EDTA in Hema&Tube brand evacuated tubes stored at 4 °C and room temperature in upright, horizontal and upside-down transport positions for up to 240 min by comparing with different stability criteria. Methods: A total of 450 outpatient samples, 75 for each condition, were stored for 240 min. Blood samples were analyzed at baseline, 60th, 120th and 240th min of storage time using Sysmex® XT-4000i hematology analyzer. CBC results were compared according to the paired samples t-test, one CV% change, CVI, BV DES 2014, RCPA, IQMH, EFLM Biological Variation 2019, ESfEQAand CLIA stability criteria. Results: In all transport conditions, almost all CBC parameters were unstable according to the paired samples t-test. Based on one CV % change RBC, hemoglobin, hematocrit, RDW-CV, neutrophils, platelets, MPV, PDW and plateletcrit were unstable in some transport conditions. However, most parameters were stable at all conditions, except especially for MCH, MPV, PDW and plateletcrit, while just MPV and PDW were unstable at RT in all transport conditions according to the lower and higher CVI, respectively. Conclusions: Paired samples t-test and one CV% change stability criteria are not suitable for decision. Clinical laboratories should establish the impact of storage time, storage temperature and transport positions for each CBC parameter while paying attention to the brand of evacuated tube according to the lower CVI of biological variation data stability criteria since it is more related to the impact of analysis deviation on clinical decisions to prevent misdiagnosis.

Related Concept Videos

Sample Handling01:02

Sample Handling

Transportation of samples from the collection point to the laboratory, as well as storage and preservation techniques, are crucial for maintaining sample integrity and ensuring accurate and reliable test results.
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
829
Drug Product Stability01:16

Drug Product Stability

The long-term stability of drug products is critical to ensuring their quality, safety, and effectiveness over time. Stability directly influences a product's ability to maintain its intended characteristics, ensuring it performs as expected during its intended shelf life. Key attributes such as drug potency, impurities, dissolution, and other physicochemical measures of performance are tested to assess stability. These parameters indicate how well the product retains its quality over time and...
108
Stability01:28

Stability

The time response of a linear time-invariant (LTI) system can be divided into transient and steady-state responses. The transient response represents the system's initial reaction to a change in input and diminishes to zero over time. In contrast, the steady-state response is the behavior that persists after the transient effects have faded.
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
300