Related Experiment Video
Updated: Dec 17, 2025

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
A detailed comparison between the endoscopic images using blue laser imaging and three-dimensional reconstructed
Takeshi Ueda1,2, Kohei Morita3, Fumikazu Koyama1,4
1Department of Surgery, Nara Medical University, Kashihara, Japan.
Abstract:
Blue laser/light imaging (BLI) is an image-enhanced endoscopy (IEE) technique that can provide an accurate diagnosis by closely observing the surface structure of various colonic lesions. However, complete correspondence between endoscopic images and pathological images has not been demonstrated. The aim of this study was to accurately compare endoscopic images and the pathological images using a three-dimensionally (3D) reconstructed pathological model. Continuous thin layer sections were prepared from colonic tissue specimens and immunohistochemically stained for CD34 and CAM5.2. Three-dimensional reconstructed images were created by superimposing immunohistochemically stained pathological images. The endoscopic image with magnifying BLI was compared with the top view of the 3D reconstructed image to identify any one-to-one correspondence between the endoscopic images and histopathological images using the gland orifices and microvessels as a guide. Using 3D reconstructed pathological images, we were able to identify the location on the endoscope image in cases of colonic adenocarcinoma, adenoma and normal mucosa. As a result, the horizontal plane of the endoscopic image and the vertical plane of the 2D pathological specimen were able to be compared, and we successfully determined the visible blood vessel depth and performed a detailed evaluation on magnifying BLI. Examples are as follows: (1) The median vasculature depth from the mucosal surface that could be recognized as vasculature on magnifying BLI was 29.4 μm. The median depth of unrecognizable vessels on magnifying BLI was 218.8 μm, which was significantly deeper than recognizable vessels. (2) Some brownish structures were suggested to potentially be not only dense vessels, vessel expansions, corrupted vessels but also bleeding or extravasation of erythrocytes. Overall, we demonstrated a new approach to matching endoscopic images and pathological findings using a 3D-reconstructed pathological model immunohistochemically stained for CD34 and CAM5.2. This approach may increase the overall understanding of endoscopic images and positively contribute to making more accurate endoscopic diagnoses.
More Related Videos
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
11:43Advanced Animal Model of Colorectal Metastasis in Liver: Imaging Techniques and Properties of Metastatic Clones
Published on: November 30, 2016
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Three-Dimensional Microscopy in Microbiology