Related Experiment Video
Updated: Dec 17, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Experimental Behavior of Cracked Reinforced Concrete Columns Strengthened with Reinforced Concrete Jacketing
Ahmed Mohamed Sayed1,2, Mohamed Mohamed Rashwan1, Mohamed Emad Helmy1
1Department of Civil Engineering, College of Engineering, Assiut University, Assiut 71511, Egypt.
Abstract:
Reinforced concrete (RC) columns often need to be strengthened or rehabilitated to allow them to carry the loads applied to them. In previous studies, RC columns have been strengthened by jacketing, without considering the occurrence of cracking. In this study, the behavior of RC columns strengthened externally by jacketing after cracking is analyzed. The accuracy of the existing models was verified by analyzing the performance of fifteen RC columns with different cross-sections to determine the effect of new variables, such as the column size, amount of steel reinforcement, and whether the column was cracked or not, on the effectiveness of strengthening. The analysis demonstrated that this strengthening technique could effectively improve both the ductility and strength of RC column cross-sections. The results indicate that the model suggested by the ACI-318 code can predict the ultimate load capacity of RC columns without strengthening, or strengthened by RC jacketing before or after cracking, with higher accuracy and material efficiency. The RC columns without strengthening met the safety limit of the ACI-318 model. However, for strengthened columns, a reduction coefficient must be used to enable the columns to meet the safety limit, with values of 94% and 76% for columns strengthened before and after cracking, respectively. Furthermore, strengthening after cracking affects the ultimate load capacity of the column, with 15.7%, 14.1%, and 13.5% lower loads for square, rectangular, and circular columns than those strengthened before cracking, respectively.
Related Concept Videos
Effects of Creep
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Types of Non-structural Cracks in Concrete
Plastic shrinkage cracks typically form within hours after the concrete is poured. The concrete's surface dries faster than the bottom, creating tensile stress that the still-plastic concrete cannot withstand, leading to diagonal or randomly patterned cracks on the concrete surface.
Design Example: Distributing Reinforcements in Concrete Sections
Fiber Reinforced Concrete
Prestressed Concrete