Related Experiment Video
Updated: Dec 17, 2025

Improved Home Blood Pressure Control by CT-guided Ozone-mediated Renal Denervation for Patients with Resistant Hypertension
Published on: June 6, 2025
Clinical Utility of Ambulatory Blood Pressure Monitoring (ABPM) in Newly Diagnosed Hypertensive Patients
Santosh B Salagre1, Anup P Khobragade2
1Professor (Addl.) and Head-Hypertension Services, Seth G. S. Medical College and K.E.M. Hospital, Parel, Mumbai, Maharashtra.
Background:
Ambulatory Blood Pressure Monitoring (ABPM) has an upper hand in diagnosing hypertension accurately. Parameters obtained by ABPM helps us in diagnosing white coat hypertension, BP variability, dipping status and blood pressure load on organs (Hyperbaric Index) reflecting possible end organ damage.
Objectives:
To evaluate clinical utility of ABPM in stage 1 newly diagnosed hypertensive subjects, to compare ABPM readings with clinic blood pressure (Clinic BP), to study dipping pattern and White Coat Hypertension (WCH) in newly labeled hypertensives.
Methodology:
After institutional ethics committee approval and written informed consent from participants, an observational cross sectional prospective study was conducted in hypertension clinic of tertiary care hospital over a period of one and half years on 138 newly diagnosed stage I hypertensive patients. ABPM results were analyzed and compared with clinic BP.
Results:
86/138 (62.32%) patients were diagnosed to have true HT by ABPM. WCH was detected in 52/138 (37.68%) which is higher than that reported in international studies (21%). The mean pulse, mean systolic/diastolic BP, mean pulse pressure and MAP were significantly higher (p<0.0001) by clinic BP than ABPM. True hypertensive patients were having higher weight (p <0.001), had higher fasting blood sugar values (p=0.008) and BUN levels (p=0.034) than WCH patients. Hyperbaric Index was significantly higher for systolic and diastolic BP in true hypertensive patients as compared to WCH patients. Patients with WCH were predominantly males (71.15%), were younger (41.82 ± 12.77 years) than true hypertensives (46.45 ± 12.20years), (p =0.037). Dipping was detected in 33 (38.37%), non-dipping in 44 (51.16%) and reverse dipping in 9 (10.47%) patients.
Conclusion:
Our study reflects the clinical utility of ambulatory blood pressure monitoring not only for accurate diagnosis of hypertension but also for assessing the various parameters of blood pressure.
Related Concept Videos
Hypertension III: Clinical Manifestations and Diagnostic Studies
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Hypertension V: Nursing Management
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:

