Dynamic Quantitative Sensory Testing to Characterize Central Pain Processing
Published on: February 16, 2017
Assessing thermal sensitivity using transient heat and cold stimuli combined with a Bayesian adaptive method in a
Arthur S Courtin1, Sofia Maldonado Slootjes1,2, Gilles Caty1,3,4,5
1Institute of Neuroscience (IoNS), Université Catholique de Louvain (UCLouvain), Brussels, Belgium.
Background:
Quantitative sensory testing of thermal detection abilities is used as a clinical tool to assess the function of pain pathways. The most common procedure to assess thermal sensitivity, the 'method of limits', provides a quick but rough estimate of detection thresholds. Here, we investigate the potential of evaluating not only the threshold but also the slope of the psychometric functions for cold and warm detection.
Method:
A convenience sample of 15 patients with diabetes mellitus (DM) and 15 age-matched healthy controls (HC) was tested. Thirty brief (100 ms) stimuli of each modality were applied to the volar wrist and foot dorsum. Cold and warm stimuli were delivered with a Peltier thermode and a temperature-controlled CO2 laser, respectively. Stimulus intensities were dynamically selected using an adaptive Bayesian algorithm (psi method) maximizing information gain for threshold and slope estimation. ROC analyses were used to assess the ability of slopes, thresholds and the combination of both to discriminate between groups.
Results:
Assessment of the slope and threshold of the psychometric function for thermal detection took about 10 min. The ability to detect warmth was not reduced in DM patients as compared to HC. Cold detection performance assessed using slope or threshold parameters separated DM from HC with good discriminative power. Discrimination was further increased when both parameters were used together (93% sensitivity and 87% specificity), indicating that they provide complementary information on patient status.
Conclusion:
The psi method may be an interesting alternative to the classical method of limits for thermal QST.
Significance:
Current QST protocols provide an incomplete and potentially biased estimate of sensory detection performance. We propose a method that estimates the slope and the threshold of the psychometric function, defining heat and cold sensory detection performance, in only a few minutes. Furthermore, we provide preliminary evidence that combining slope and threshold parameters of cold detection performance leads to a better discriminative ability than relying solely on the threshold.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Thermosensation
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...