Estimation of dairy goat body composition: A direct calibration and comparison of eight methods
Sylvain Lerch1, Anne De La Torre2, Christophe Huau3
1Agroscope, Ruminant Research Unit, Route de la Tioleyre 4, 1725 Posieux, Switzerland.
Abstract:
The objective was to compare eight methods for estimation of dairy goat body composition, by calibrating against chemical composition (water, lipid, protein, mineral and energy) measured post-mortem. The methods tested on 20 Alpine goats were body condition score (BCS), 3-dimension imaging (3D) automatic assessment of BCS or whole body scan, ultrasound, computer tomography (CT), adipose cell diameter, deuterium oxide dilution space (D2OS) and bioelectrical impedance spectroscopy (BIS). Regressions were tested between predictive variates derived from the methods and empty body (EB) composition. The best equations for estimation of EB lipid mass included BW combined with i) perirenal adipose tissue mass and cell diameter (R2 = 0.95, residual standard deviation, rSD = 0.57 kg), ii) volume of fatty tissues measured by CT (R2 = 0.92, rSD = 0.76 kg), iii) D2OS (R2 = 0.91, rSD = 0.85 kg), and iv) resistance at infinite frequency from BIS (R2 = 0.87, rSD = 1.09 kg). The D2OS combined with BW provided the best equation for EB protein mass (R2 = 0.97, rSD = 0.17 kg), whereas BW alone provided a fair estimate (R2 = 0.92, rSD = 0.25 kg). Sternal BCS combined with BW provided good estimation of EB lipid and protein mass (R2 = 0.80 and 0.95, rSD = 1.27 and 0.22 kg, respectively). Compared to manual BCS, BCS by 3D slightly decreased the precision of the predictive equation for EB lipid (R2 = 0.74, rSD = 1.46 kg), and did not improve the estimation of EB protein compared with BW alone. Ultrasound measurements and whole body 3D imaging methods were not satisfactory estimators of body composition (R2 ≤ 0.40). Further developments in body composition techniques may contribute for high-throughput phenotyping of robustness.
More Related Videos
06:48Author Spotlight: Advancements in 3D Optical Imaging for Comprehensive Body Composition Assessment in Modern Research
Published on: June 7, 2024
08:22Using Deuterium Oxide as a Non-Invasive, Non-Lethal Tool for Assessing Body Composition and Water Consumption in Mammals
Published on: February 20, 2020
Related Concept Videos
Measurement of Bioavailability: Pharmacokinetic Methods
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Measurement of Bioavailability: Pharmacodynamic Methods
Estimation of the Physical Quantities
Microbial Growth Measurement: Indirect Methods