A modelling framework for assessment of arterial compliance by fusion of oscillometry and pulse wave velocity information
Related Experiment Video
Updated: Dec 16, 2025

Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Laura I Bogatu1, Simona Turco2, Massimo Mischi2
1Patient Care and Measurements, Philips Research, Eindhoven, 5656 AE, Netherlands; Biomedical Diagnostics, Eindhoven University of Technology, Eindhoven, 5612 AZ, Netherlands.
Background And Objectives:
Measurement of arterial compliance is recognized as important for clinical use and for enabling better understanding of circulatory system regulation mechanisms. Estimation of arterial compliance involves either a direct measure of the ratio between arterial volume and pressure changes or an inference from the pulse wave velocity (PWV). In this study we demonstrate an approach to assess arterial compliance by fusion of these two information sources. The approach is based on combining oscillometry as used for blood pressure inference and PWV measurements based on ECG/PPG. Enabling reliable arterial compliance measurements will contribute to the understanding of regulation mechanisms of the arterial tree, possibly establishing arterial compliance as a key measure relevant in hemodynamic monitoring.
Methods:
A measurement strategy, a physiological model, and a framework based on Bayesian principles are developed for measuring changes in arterial compliance based on combining oscillometry and PWV data. A simulation framework is used to study and validate the algorithm and measurement principle in detail, motivated by previous experimental findings.
Results:
Simulations demonstrate the possibility of inferring arterial compliance via fusion of simultaneously acquired volume/pressure relationships and PWV data. In addition, the simulation framework demonstrates how Bayesian principles can be used to handle low signal - to - noise ratio and partial information loss.
Conclusions:
The developed simulation framework shows the feasibility of the proposed approach for assessment of arterial compliance by combining multiple data sources. This represents a first step towards integration of arterial compliance measurements in hemodynamic monitoring using existing clinical technology. The Bayesian approach is of particular relevance for such patient monitoring settings, where measurements are repeated frequently, context is relevant, and data is affected by artefacts. In addition, the simulation framework is necessary for future clinical-study design, in order to determine device specifications and the extent to which noise affects the inference process.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: