Diagnostic performances and unnecessary US-FNA rates of various TIRADS after application of equal size thresholds

Sun Huh1, Hye Sun Lee2, Jiyoung Yoon1

  • 1Department of Radiology, Research Institute of Radiological Science, and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Seoul, Korea.

Scientific Reports
|July 2, 2020
PubMed

Insights

Modified thyroid nodule guidelines, particularly the mKwak, improve diagnostic accuracy and reduce unnecessary fine-needle aspirations (FNA). Applying the ACR TIRADS size threshold enhances performance across multiple thyroid imaging reporting and data systems (TIRADS) guidelines.

Area of Science:

  • Radiology
  • Oncology
  • Diagnostic Imaging

Background:

  • Thyroid nodule evaluation relies on various imaging guidelines.
  • Optimizing these guidelines can improve diagnostic accuracy and reduce unnecessary procedures like fine-needle aspiration (FNA).

Purpose of the Study:

  • To compare the diagnostic performance and unnecessary FNA rates of established and modified thyroid nodule imaging guidelines.
  • To evaluate the impact of incorporating the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TIRADS) size threshold into other TIRADS guidelines.

Main Methods:

  • A retrospective study included 1,384 thyroid nodules from 1,301 patients with cytopathologic findings.
  • Ultrasound (US) categories were assigned per guideline. ACR TIRADS size thresholds were applied to Kwak, ATA, and EU guidelines, creating modified versions (mKwak, mATA, mEU).
  • Diagnostic performance metrics (specificity, accuracy, likelihood ratio (LR), area under the curve (AUC)) and unnecessary FNA rates were evaluated.

Main Results:

  • The original ACR TIRADS showed the highest performance among initial guidelines (specificity 62.2%, accuracy 66%, LR 2.128, AUC 0.713).
  • Modified guidelines (mKwak, mATA, mEU) demonstrated significantly improved specificity, accuracy, LR, and AUC compared to their original versions (P < 0.001).
  • The mKwak guideline achieved the highest overall performance (specificity 64%, accuracy 68.6%, LR 2.389, AUC 0.75) with the lowest unnecessary FNA rate (61.1%).

Conclusions:

  • Incorporating the ACR TIRADS size threshold into other TIRADS guidelines enhances diagnostic accuracy and reduces unnecessary FNAs.
  • The modified Kwak (mKwak) guideline demonstrates superior diagnostic performance for thyroid nodules.
  • These findings support the optimization of TIRADS guidelines for more efficient and accurate thyroid nodule management.