Related Experiment Video
Updated: Dec 16, 2025

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Hospital-Acquired Serum Chloride Derangements and Associated In-Hospital Mortality
Charat Thongprayoon1, Wisit Cheungpasitporn2, Tananchai Petnak3,4
1Division of Nephrology and Hypertension, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA.
Abstract:
Background: We aimed to describe the incidence of hospital-acquired dyschloremia and its association with in-hospital mortality in general hospitalized patients. Methods: All hospitalized patients from 2009 to 2013 who had normal admission serum chloride and at least two serum chloride measurements in the hospital were studied. The normal range of serum chloride was defined as 100-108 mmol/L. Hospital serum chloride levels were grouped based on the occurrence of hospital-acquired hypochloremia and hyperchloremia. The association of hospital-acquired hypochloremia and hyperchloremia with in-hospital mortality was analyzed using logistic regression. Results: Among the total of 39,298 hospitalized patients, 59% had persistently normal hospital serum chloride levels, 21% had hospital-acquired hypochloremia only, 15% had hospital-acquired hyperchloremia only, and 5% had both hypochloremia and hyperchloremia. Compared with patients with persistently normal hospital serum chloride levels, hospital-acquired hyperchloremia only (odds ratio or OR 2.84; p < 0.001) and both hospital-acquired hypochloremia and hyperchloremia (OR 1.72; p = 0.004) were associated with increased in-hospital mortality, whereas hospital-acquired hypochloremia only was not (OR 0.91; p = 0.54). Conclusions: Approximately 40% of hospitalized patients developed serum chloride derangements. Hospital-acquired hyperchloremia, but not hypochloremia, was associated with increased in-hospital mortality.
More Related Videos
07:30Design of Cecal Ligation and Puncture and Intranasal Infection Dual Model of Sepsis-Induced Immunosuppression
Published on: June 15, 2019
05:16Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Published on: June 10, 2025
Related Concept Videos
Roles of Electrolytes: Chloride and Bicarbonate
Conditions such as hypochloremia can arise from insufficient chloride reabsorption by the kidneys, often compounded by extended bouts of diarrhea, vomiting,...
Hemodialysis II: Procedure and Complications
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Serum Studies: Renal Function Tests
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Acute Kidney Injury V: Interprofessional Care