Related Experiment Video
Updated: Dec 16, 2025

Probe-based Confocal Laser Endomicroscopy of the Urinary Tract: The Technique
Published on: January 10, 2013
Fluorescence Imaging of the Ureter in Minimally Invasive Pelvic Surgery
Warner K Huh1, John L Johnson1, Emily Elliott1
1Division of Gynecologic Oncology, University of Alabama, Birmingham, Alabama (Drs. Kim, Johnson, Leath III, Huh, and Ms. Elliott); Department of Obstetrics and Gynecology, University of Tennessee Medical Center Knoxville, Graduate School of Medicine, Knoxville, Tennessee (Dr. Boone); Clinical Research and Development, LI-COR, Inc., Lincoln, Nebraska (Ms. Kovar).
Study Objective:
Determine near-optimal dose, safety, and efficacy of nerindocianine in pelvic ureter detection with near-infrared fluorescence imaging in women undergoing minimally invasive pelvic surgery with 3 Food and Drug Administration-cleared imaging systems.
Design:
Open label, phase 1/2a study.
Setting:
University of Alabama at Birmingham.
Patients:
Forty-one female subjects undergoing minimally invasive gynecologic surgery.
Interventions:
Subjects received a single dose of nerindocianine sodium, starting at 0.06-mg/kg body weight and increased/decreased until the near-optimal dose was determined (part A). Examine the degree of concordance between endoscopic and robotic devices (part B).
Measurements And Main Results:
In part A, composite scores were collected every 10 minutes for 30 minutes and then every 15 minutes through 90 minutes using a scale measuring the anatomy/laterality of ureter visualization. In part B (paired imaging system efficacy), 2 cohorts of 8 subjects each received the near-optimal dose. Composite scores for visualization of the ureter were collected at 10 and 30 minutes postinfusion with the Firefly Imaging System and either the PINPOINT or 1588 AIM endoscope. Composite scores were compared to examine the degree of concordance between devices. Part A comprised 25 total subjects enrolled in dosing groups 1, 2, and 3 (0.06-, 0.12-, and 0.045-mg/kg, respectively). Median time to first ureter visualization was 10 minutes (all groups). The nerindocianine 0.06-mg/kg and 0.12-mg/kg groups had longer length of time of visualization than the 0.045-mg/kg group, resulting in the selection of 0.06 mg/kg as the near-optimal dose. Part B enrolled 16 total subjects in 2 groups dosed at 0.06 mg/kg. Efficacy analysis showed no statistically significant difference in composite scores with Firefly versus PINPOINT or 1588 AIM.
Conclusion:
Nerindocianine was well tolerated with visualization of the ureter demonstrated in 88.9% of the subjects through 90 minutes postdosing. No meaningful visualization differences were observed among the Food and Drug Administration-cleared surgical imaging systems used.
More Related Videos
06:37Multispectral Real-time Fluorescence Imaging for Intraoperative Detection of the Sentinel Lymph Node in Gynecologic Oncology
Published on: October 20, 2010
06:39Technical Modification of the Terminal Ureter During Total Transperitoneal Laparoscopic Nephroureterectomy for Upper Urinary Tract Urothelial Carcinoma
Published on: November 22, 2019
Related Concept Videos
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies II: Ultrasonography
Urologic Endoscopic Procedure: Cystoscopic Examination
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies III: Computed Tomography