Related Experiment Video
Updated: Dec 16, 2025

A Swine Model of Neonatal Asphyxia
Published on: October 11, 2011
Management of fetal ductus arteriosus constriction with Digoxin and oxygen therapy
Alina Z Naqvi1, Susan M Lanni2, Joanna B Rosenthal3
1Virginia Commonwealth University School of Medicine, Richmond, VA, USA.
Abstract:
Constriction of the fetal ductus arteriosus is rare and usually attributed to medications or CHD. We describe a 24-year-old multigravida at 33 weeks 5 days gestation with echocardiographic findings of severe ductal constriction, a dilated, hypertrophied and hypocontractile right ventricle, and severe tricuspid regurgitation following BC powder® use. Treatment with Digoxin and oxygen resulted in a progressive 71% reduction in peak systolic ductal gradient, improved right ventricular function, and decreased tricuspid regurgitation.
More Related Videos
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Mitral Stenosis III: Medical Management
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Mitral Stenosis IV: Nursing Management
Cardiomyopathy II: Dilated Cardiomyopathy
Heart Failure V: Medical Management