Related Experiment Video
Updated: Dec 16, 2025

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Effective doses of dental cone beam computed tomography: effect of 360-degree versus 180-degree rotation angles
Sunil Mutalik1, Aditya Tadinada2, Marco R Molina3
1Sessional Faculty, University of Manitoba, Gerald Niznick College of Dentistry, Winnipeg, MB, Canada.
Objectives:
The aims of this study were to compare radiation absorbed dose (AD) and effective dose (ED) to tissues from cone beam computed tomography (CBCT) scans with 360-degree versus 180-degree rotations with use of different fields of view (FOV), to compare EDs calculated from measured ADs versus dose area product (DAP) values, and to compare doses to the lens of the eye (LOE) from different scan parameters.
Study Design:
ADs for each protocol were measured in tissues, including the LOE, by using an anthropometric phantom. EDs were calculated on the basis of dosimetry (EDm) and DAP values (EDd). Dose differences were determined with analysis of variance (ANOVA).
Results:
ADs and EDs were substantially lower for 180-degree rotation scans compared with 360-degree rotation scans (P < .01). Remainder tissues had the greatest effect on effective dose for most FOVs. Doses were generally lower with small FOVs compared with large FOVs. Most EDm values were lower than EDd values in large FOVs but higher in small FOVs. Differences in EDm and EDd were variable and unpredictable. LOE doses were smaller with the 180-degree scans and smaller FOVs.
Conclusions:
Radiation doses were generally lower with 180-degree rotation scans and smaller FOVs. These parameters should be used for CBCT acquisitions, whenever possible, and should be made available in all units.
More Related Videos
09:10Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures
Published on: August 5, 2021
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography