Related Experiment Video
Updated: Dec 16, 2025

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Eye Globe Rupture Caused by Dental Implant-Related Maxillary Sinusitis
Sung-Tak Lee1, So-Young Choi2, Tae-Geon Kwon3
1Assistant Professor, Department of Oral & Maxillofacial Surgery, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea.
Abstract:
Eye globe rupture with consequent enucleation is an extremely rare complication of orbital infection spreading from maxillary sinusitis related to dental implant surgery. We report a case of orbital abscess leading to rupture of the globe of the eye in a 60-year-old woman with acute unilateral maxillary sinusitis after dental implant surgery on the left maxillary alveolar bone. The patient had uncontrolled diabetes. Despite surgical intervention, infection of the maxillary sinuses spread to the ocular area, causing disastrous results. To our knowledge, this entity has not been reported previously.
Related Concept Videos
Glaucoma: Overview
Angle Closure Glaucoma: Treatment