The effect of the entry and re-entry size in the aortic dissection: a two-way fluid-structure interaction simulation
Hamed Keramati1,2, Erik Birgersson3, Jackie P Ho4,5
1NUS Graduate School for Integrative Sciences and Engineering, National University of Singapore, Singapore, Singapore.
Abstract:
Aortic dissection (AD) is one of the most catastrophic cardiovascular diseases. AD occurs when a layer inside the aorta is disrupted and gives rise to the formation of a true lumen and a false lumen. These lumens can be connected through tears in the intimal flap which are known as entries. Despite being known for about two centuries, the effects of many factors on the morbidity and mortality of this disease are still unknown. As the blood interaction with the aorta is crucial in the severity and the progression of the aortic dissection, a biomechanical approach is chosen to investigate the influence of different morphologies on the severity of this disease. Using the finite element method (FEM) and the fluid-structure interaction (FSI) approach, we have evaluated the blood flow characteristics along the diseased aorta, in conjunction with the deformation of the aortic wall. In this study, an idealized geometry of a dissected descending aorta (type B) with two entries has been studied. The values for the diameter of the entry tear were chosen to be 5 mm and 10 mm. Therefore, a total of four conditions were investigated. According to our results, the retrograde flow through the proximal tear is dependent on the size of the distal re-entry and vice versa. Our results revealed that when both entry and re-entry tears are 10 mm in diameter, the flow passes through the true and false lumens with smaller resistance, resulting in a smaller flutter of the intimal flap, and therefore more stable intimal flap. Major oscillation frequencies of 2.5 Hz and 7.4 Hz were observed for the oscillation of the intimal flap, and amplitudes of the waves with higher frequencies were negligible.
More Related Videos
11:16In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016