Critical evaluation of equations for serum osmolality: Proposals for effective clinical utility
Emmanuel O Ebonwu1, Susanna E Nagel2, Lisa Repsold3
1Tshwane University of Technology (TUT), Staatsartillerie Rd, Pretoria-West, Pretoria 0183, South Africa; Department of Chemical Pathology, Faculty of Health Sciences, University of Pretoria and National Health Laboratory Service (NHLS) Tshwane Academic Division, Pretoria, South Africa.
Background:
Many studies have assessed the predictive accuracy of serum osmolality equations. Different approaches for selecting a usable equation were compared using thirty published equations and patient data from a regional hospital laboratory.
Methods:
Laboratory records were extracted with same-sample results for measured serum osmolality, sodium, potassium, urea and glucose analysed in a regional hospital laboratory between 1/1/2017-31/12/2018. Differences were analysed using Passing-Bablok and difference (Bland-Altman) analysis. Three approaches were compared: the shotgun approach, adjusting for bias, and deriving a novel equation using multivariate analysis. The criteria for success included bias ≤0.7%, a 230 - 400 mOsm/kg range, and osmolal gap (OG) 95% reference limits within ±10 mOsm/kg.
Results:
The majority of equations produced proportionally negative-biased results. The shotgun approach identified two equations (EQ19, EQ6) with bias ≤0.7% but unworkable OG reference limits. The bias adjustment approach produced several equations with bias ≤ 0.7% and OG reference limits within or equivalent to ±10 mOsm/kg. A novel equation generated by us (1.89Na+ + 1.71 K+ + 1.08 Urea + 1.08 Glucose + 13.7) improved with the adjustment of bias and was not superior to the adjusted published equations.
Conclusion:
Few published equations are immediately usable. Adjustment of bias derives several usable equations of which the best had OG ranges <20 mOsm/kg. We conclude that adjustment of bias can generate equations of equal or superior performance to that of novel equations.
Related Concept Videos
Serum Studies: Renal Function Tests
Osmosis and Osmotic Pressure of Solutions
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Expressing Solution Concentration
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance