Related Experiment Video
Updated: Dec 16, 2025

Procedure for Human Saphenous Veins Ex Vivo Perfusion and External Reinforcement
Published on: October 1, 2014
Is there a "safe" suction pressure in the venous line of extracorporeal circulation system?
Yuri M Ganushchak1, Erik Pj Körver1, Jos G Maessen1,2
1Department of Cardiothoracic Surgery, Maastricht University Medical Center, Maastricht, The Netherlands.
Abstract:
Successes of extracorporeal life support increased the use of centrifugal pumps. However, reports of hemolysis call for caution in using these pumps, especially in neonatology and in pediatric intensive care. Cavitation can be a cause of blood damage. The aim of our study was to obtain information about the cavitation conditions and to provide the safest operating range of centrifugal pumps. A series of tests were undertaken to determine the points at which pump performance decreases 3% and gas bubbles start to appear downstream of the pump. Two pumps were tested; pump R with a closed impeller and pump S with a semiopen impeller. The performance tests demonstrated that pump S has an optimal region narrower than pump R and it is shifted to the higher flows. When the pump performance started to decrease, the inlet pressure varies but close to -150 mmHg in the test with low gas content and higher than -100 mmHg in the tests with increased gas content. The same trend was observed at the points of development of massive gas emboli. Importantly, small packages of bubbles downstream of the pump were registered at relatively high inlet pressures. The gaseous cavitation in centrifugal pumps is a phenomenon that appears with decreasing inlet pump pressures. There are a few ways to increase inlet pump pressures: (1) positioning the pump as low as possible in relation to the patient; (2) selecting appropriate sized venous cannulas and their careful positioning; and (3) controlling patient's volume status.
More Related Videos
Related Concept Videos
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Capillary Exchange
Veins as Blood Reservoirs
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy