Indoor Air Quality in Passivhaus Dwellings: A Literature Review
Alejandro Moreno-Rangel1, Tim Sharpe2, Gráinne McGill2
1Lancaster Institute the Contemporary Arts, Lancaster University, Bailrigg, Lancaster LA1 4YW, UK.
Abstract:
Indoor air quality (IAQ) is a critical consideration in airtight buildings that depend on mechanical ventilation, such as those constructed to the Passivhaus standard. While previous reviews of IAQ on Passivhaus-certified buildings foccused on offices, this study examines residential buildings. A summary of data collection methods and pollutant concentrations is presented, followed by a critical discussion of the impact of Passivhaus design strategies on IAQ. This review indicates that IAQ in Passivhaus-certified dwellings is generally better than in conventional homes, but both occupant behaviour and pollution from outdoor sources play a significant role in indoor concentrations. Moreover, there are differences in data collection and reporting methods. Many of the available studies depend on short-term IAQ monitoring of less than two weeks, making it difficult to determine the longer impact of housing design on IAQ and occupants' well-being. There is also a lack of studies from non-European countries. Future research should focus on investigating associations between IAQ and Passivhaus design strategies in hot and humid climates, where evidence is particularly lacking. Further effort is also required to investigate potential links between occupant's perception of IAQ and physical exposure to indoor pollution. Finally, the lack of homogeneous monitoring and reporting methods for IAQ studies needs to be addressed.
More Related Videos
Related Concept Videos
Passive Diffusion: Overview and Kinetics
When administered orally, drugs establish a substantial concentration gradient between the gastrointestinal (GI) lumen and the bloodstream, expediting...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...