Contrast-enhanced ultrasound (CEUS) reliably rules out neoplasm in developmental renal pseudotumor
Paul Spiesecke1, Thomas Fischer1, Andreas Maxeiner2
1Department of Radiology, Charité - Universitätsmedizin Berlin, Berlin, Germany.
Background:
Renal pseudotumors appear as benign cortical hypertrophies and are typically assessed by contrast-enhanced computed tomography or magnetic resonance imaging to rule out malignancy.
Purpose:
To investigate whether contrast-enhanced ultrasound (CEUS) can rule out renal neoplasm and thus potentially reduce cross-sectional imaging and further follow-up in these patients.
Material And Methods:
Thirty-two patients with presumption of developmental renal pseudotumor on CEUS between June 2011 and July 2019 were retrospectively analyzed. All patients were examined with a standardized renal US protocol including B-mode, color-coded duplex sonography (CCDS), and CEUS by an experienced radiologist (EFSUMB level 3). Images were retrospectively interpreted in consensus by two highly experienced radiologists. Histopathological reports, cross-sectional imaging findings, and clinical course (treatment response, long-term imaging follow-up) were defined as standard of reference.
Results:
CEUS correctly identified 8/9 neoplastic lesions and missed one oncocytoma within the 32 included patients. Irregular vessel structure (88.9% vs. 13.0%, P = 0.007) and hyperenhancement (66.6% vs. 17.4%, P = 0.031) on CEUS were more common in neoplasm compared to developmental pseudotumors reaching statistical significance. Compared with the standard of reference, CEUS had 89% sensitivity (95% confidence interval [CI] 57-98), 96% specificity (95% CI 80-99), a positive predictive value of 89% (95% CI 57-98), and a negative predictive value of 96% (95% CI 79-99) for ruling out renal malignancy in developmental pseudotumors.
Conclusion:
CEUS is a safe and fast method to rule out neoplasm in the diagnostic work-up of renal pseudotumors. In conjunction with B-mode and CCDS, CEUS has the potential to reduce further (invasive) diagnostic procedures.
Related Concept Videos
Imaging Studies II: Ultrasonography
Imaging Studies III: Computed Tomography
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies IV: Magnetic Resonance Imaging