Related Experiment Video
Updated: Dec 15, 2025

A New Murine Model of Endovascular Aortic Aneurysm Repair
Published on: July 7, 2013
Endovascular relining of a Dacron graft for refractory perigraft seroma
Shinji Abe1, Yasuhiro Kamikubo2, Yasushige Shingu3
1Department of Cardiovascular Surgery, Kushiro-City General Hospital, 1-12 Shunkodai, Kushiro, 085-0822, Japan. shinabe_mail@yahoo.co.jp.
Abstract:
Although perigraft seroma (PGS) is a well-known complication of vascular surgery, optimal therapy has not yet been established. A 90-year-old patient underwent a bypass from the right subclavian artery to the left carotid and subclavian arteries for debranching thoracic endovascular aortic repair. Four years post-surgery, computed tomography revealed PGS at the anastomosis site. Percutaneous needle aspiration and surgical drainage were ineffective in treating PGS. We performed a relining procedure using covered stents for the bypass graft that resolved the PGS. This procedure is minimally invasive, avoids graft excision, and can be especially valuable for elderly patients.