Related Experiment Video
Updated: Dec 15, 2025

Symptom Assessment of Patients with Allergic Rhinitis Using an Allergen Exposure Chamber
Published on: March 3, 2023
Indoor air quality and sick building syndrome in a university setting: a case study in Greece
Efthymia Tsantaki1, Emmanouil Smyrnakis1, Theodoros C Constantinidis2
1Laboratory of Primary Health Care, General Practice and Health Services Research, Department of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Abstract:
The perceived Indoor Air Quality (IAQ), the prevalence of Sick Building Syndrome (SBS) symptoms and its contributing risk factors were assessed in a university during the period of the economic crisis in Greece. Data was collected from 613 employees via questionnaires. Hierarchical linear regression analysis was performed. The most prevalent perceived IAQ complaints were 'Dust and dirt' (63.2%), 'Room temperature too low' (24.9%) and 'Varying room temperature' (24.4%). The most frequently reported SBS symptom was 'Fatigue' (34.1%). The prevalence of General, Mucosal and Dermal symptoms was 40.8%, 19.8% and 8.1%, respectively. Several contributing risk factors were identified, such as IAQ Discomfort Scale, atopy, sleep problems, female, exposure to biological and chemical agents, PC-use, Psychosocial Work Scale and job satisfaction. Poor perceived IAQ and high prevalence of SBS symptoms were reported from the university staff in a temperate climate country. SBS seemed to be multifactorial.
More Related Videos
Related Concept Videos
Asthma-I: Introduction
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Asthma-III: Symptoms and Complications
Classification of Asthma