Efficient Estimation of CFO-Affected OFDM BER Floor in Small Cells with Resource-Limited IoT End-Points

Adriana Lipovac1, Vlatko Lipovac1, Borivoj Modlic2

  • 1Department of Electrical Engineering and Computing, University of Dubrovnik, 20000 Dubrovnik, Croatia.

Related Concept Videos

Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
523
Estimation of the Physical Quantities01:05

Estimation of the Physical Quantities

On many occasions, physicists, other scientists, and engineers need to make estimates of a particular quantity. These are sometimes referred to as guesstimates, order-of-magnitude approximations, back-of-the-envelope calculations, or Fermi calculations. The physicist Enrico Fermi was famous for his ability to estimate various kinds of data with surprising precision. Estimating does not mean guessing a number or a formula at random. Instead, estimation means using prior experience and sound...
7.0K
Determination of Expected Frequency01:08

Determination of Expected Frequency

Suppose one wants to test independence between the two variables of a contingency table. The values in the table constitute the observed frequencies of the dataset. But how does one determine the expected frequency of the dataset? One of the important assumptions is that the two variables are independent, which means the variables do not influence each other. For independent variables, the statistical probability of any event involving both variables is calculated by multiplying the individual...
2.5K
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
513
Sample Size Calculation01:19

Sample Size Calculation

Knowledge of the sample size is the first requirement to conduct random sampling or an experiment. The sample size is the total number of units, observations, or groups (in some cases) used to get the data to estimate a population parameter. As the name suggests, the sample size is that of the sample drawn from the population and differs from the population size.
The sample size for the given experiment or sampling effort is fundamental to any study design. Sample size decides the number of...
6.0K
Maximum Power Transfer01:16

Maximum Power Transfer

Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
718