Related Experiment Video
Updated: Dec 15, 2025

Ultrasound Cyclo Plasty in Eyes with Glaucoma
Published on: January 26, 2018
Evaluating Goldmann Applanation Tonometry Intraocular Pressure Measurement Agreement Between Ophthalmic Technicians
Aleksandra Mihailovic1, Varshini Varadaraj1, Pradeep Y Ramulu1
1Glaucoma Center of Excellence, Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
Purpose:
To examine IOP measurement disagreement between technicians and physicians and the impact of an educational intervention on the short and long-term disagreement in IOP measurement using Goldmann applanation tonometry.
Design:
Prospective study designed to enhance measurement reliability.
Setting:
A glaucoma clinic at a university hospital. StudyPopulation: 6 technicians and 2 physicians.
Intervention:
An educational intervention was implemented for the technicians to improve IOP measurement agreement with physicians. MainOutcomeMeasures: Frequency of IOP measurement disagreement between physicians and technicians, defined as a difference in IOP of >2 or >3 mm Hg and assessed at baseline and immediately and 6 months postintervention.
Results:
IOP was evaluated for a total of 529 eyes (physician measured mean IOP = 16.4 mm Hg [SD = 5.9]), 30 per technician-physician pair for each data collection period: baseline, immediately postintervention and 6 months postintervention. At baseline, physicians disagreed 17% and 7% of the time when measuring IOP using >2 and >3 mm Hg to define disagreement, respectively, whereas the average disagreement between technicians and physicians was 25% and 13%. Disagreement was greater at IOPs greater than 20 mm Hg. No significant changes were noted in the frequency of disagreement between technicians and physicians immediately or 6 months postintervention.
Conclusions:
Two physicians measuring the same patient in the same room disagreed by >2 mm Hg in 17% of patients' eyes, and this amount of disagreement was even higher when comparing physicians to certified technicians. An educational intervention did not improve agreement in IOP measurements between technicians and physicians. This highlights an important limitation of Goldmann tonometry.
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure

