Related Experiment Video
Updated: Dec 15, 2025

Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training
Published on: January 18, 2021
Three-dimensional nonlinear finite element model to estimate backflow during flow-controlled infusions into the brain
Gustavo A Orozco1, Joshua H Smith2, José J García3
1Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.
Abstract:
Convection-enhanced delivery is a technique to bypass the blood-brain barrier and deliver therapeutic drugs into the brain tissue. However, animal investigations and preliminary clinical trials have reported reduced efficacy to transport the infused drug in specific zones, attributed mainly to backflow, in which an annular gap is formed outside the catheter and the fluid preferentially flows toward the surface of the brain rather than through the tissue in front of the cannula tip. In this study, a three-dimensional human brain finite element model of backflow was developed to study the influence of anatomical structures during flow-controlled infusions. Predictions of backflow length were compared under the influence of ventricular pressure and the distance between the cannula and the ventricles. Simulations with zero relative ventricle pressure displayed similar backflow length predictions for larger cannula-ventricle distances. In addition, infusions near the ventricles revealed smaller backflow length and the liquid was observed to escape to the longitudinal fissure and ventricular cavities. Simulations with larger cannula-ventricle distances and nonzero relative ventricular pressure showed an increase of fluid flow through the tissue and away from the ventricles. These results reveal the importance of considering both the subject-specific anatomical details and the nonlinear effects in models focused on analyzing current and potential treatment options associated with convection-enhanced delivery optimization for future clinical trials.
Related Concept Videos
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Three-Compartment Open Model
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...

