Related Experiment Video
Updated: Dec 15, 2025

Rapid Nanoprobe Signal Enhancement by In Situ Gold Nanoparticle Synthesis
Published on: March 7, 2018
Ionic Strength Influences on Biofunctional Au-Decorated Microparticles for Enhanced Performance in Multiplexed
Susana Díaz-Amaya1,2, Min Zhao3, Jan P Allebach3
1Department of Materials Engineering, Purdue University. West Lafayette, Indiana 47907, United States.
Abstract:
The rising development of biosensors offers a great potential for health, food, and environmental monitoring. However, in many colorimetric platforms, there is a performance limitation stemming from the tendency of traditional Au nanoparticles toward nonspecific aggregation in response to changing ionic strength (salt concentration). This work puts forward a new type of colorimetric aptamer-functionalized labeling of microparticles, which allows to leverage an increase in ionic strength as a positive driver of enhanced detection performance of analytical targets. The resulting device is a cost-effective, instrument-free, portable, and reliable aptasensor that serves as basis for the fabrication of universal paper-based colorimetric platforms with the capability of multiplex, multireplicates and provides quantitative colorimetric detection. A controlled fabrication process was demonstrated by keeping 90% of the signal obtained from the as-fabricated devices (n = 40) within ± 1 standard deviation (SD) (relative SD = 5.69%) and following a mesokurtic normal-like distribution (p = 0.385). We propose for the first time a salt-induced aggregation mechanism for highly stable multilayered label particles (ssDNA-PEI-Au-PS) as the basis of the detection scheme. The use of DNA aptamers as capture biomolecules and PEI as an encapsulating agent allows for a sensitive and highly specific colorimetric response. As a proof of concept, multiplexed detection of mercury (Hg2+) and arsenic (As3+) was demonstrated. In addition, we introduced a robust image analysis algorithm for testing zone segmentation and color signal quantification that allowed for analytical detection, reaching a limit of detection of 1 ppm for both targeted analytes, with enough evidence (p > 0.05) to prove the high specificity of the fabricated device versus a pool of possible interferent ions.
More Related Videos
Related Concept Videos
Ionic Strength: Effects on Chemical Equilibria
In this solution, the primary...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
Complexometric Titration: Ligands
Complexometric Titration: Overview