Related Experiment Video
Updated: Dec 15, 2025

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Performance of the CoreValve Evolut R and PRO in Severely Calcified Anatomy: A Propensity Score Matched Analysis
Kerstin Piayda1, Katharina Hellhammer1, Verena Veulemans1
1Medical Faculty, Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
Background:
The CoreValve Evolut R and PRO (Medtronic, Minneapolis, MN, USA) are among the newest-generation of self-expandable transcatheter aortic valve replacement (TAVR) devices and show excellent results. Treating patients with severely calcified (SC) native aortic valve anatomy may be challenging because of the increased risk of periprocedural complications. This study investigated the performance of Evolut R and PRO in this special patient subset.
Methods:
Patients who underwent TAVR with the CoreValve Evolut R or PRO (n=381) from September 2015 to March 2018 were divided by aortic valve calcification extent. Patients with SC aortic valve anatomy (n=98; men, >2,062 and women, >1,377 Agatston units) were compared with those with non-severely calcified (NCS) aortic valve anatomy after 1:2 propensity score matching. Outcomes were evaluated according to the updated valve academic research consortium criteria.
Results:
Patients with SC anatomy were older (83 years vs 80 years, p<0.001) and had a smaller aortic valve area (0.63 cm2 vs 0.70 cm2, p=0.028). Pre-dilatation was more often performed (30.6% vs 15.8%, p=0.003) and a permanent pacemaker implantation was more often necessary (32.9% vs 8.8%, p<0.001) in the SC group. None/mild aortic regurgitation (AR) was evenly distributed (SC, 96.9% vs NCS, 99.5%, p=0.109); moderate AR was present in 3.1% of SC patients and in 0.5% of NSC patients. Severe AR was not observed.
Conclusion:
The CoreValve Evolut R and PRO showed good clinical safety profiles and excellent haemodynamic results in patients with SC anatomy and who more often required permanent pacemaker implantation.
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Mitral Stenosis III: Medical Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Mitral Valve Prolapse I: Introduction
Mitral Stenosis I: Introduction