Development of a multiple regression model to calibrate a low-cost sensor considering reference measurements and
Yovitza Romero1, Ricardo Manuel Arias Velásquez2, Julien Noel2
1Energy Engineering Department, Universidad de Ingenieria y Tecnologia - UTEC, Lima, Peru. yovitza.romero@gmail.com.
Abstract:
Low-cost air quality sensors are widely used to improve temporal and spatial resolution of air quality data. In Lima, Peru, only a limited number of reference air quality monitors have been installed, which has led to a lack of data for establishing environmental and health policies. Low-cost technology is promising for developing countries because it is small and inexpensive to operate and maintain. However, considerable work remains to be done to improve data quality. In this study, a low-cost sensor was installed with a reference monitor station as the first stage for the calibration process, and a multiple regression model was developed based on reference measurements as an outcome variable using sensor data, temperature, and relative humidity as the predictive parameters. The results show that this particular technology exhibits a promising performance in measuring PM2.5 and PM10 (particulate matter with diameter aerodynamic less than 2.5 μm and 10 μm, respectively); however, the correlation for PM2.5 appears to be better. Temperature and relative humidity data from the sensor were only partially analyzed due to the evident low correlation with the reference meteorological data. The objective of this study is to begin analyzing the performance of low-cost sensors that have already been introduced to the Peruvian market and selecting those that perform better to provide for informed decision-making.
More Related Videos
05:56Construction of a Compact Low-Cost Radiation Shield for Air-Temperature Sensors in Ecological Field Studies
Published on: November 6, 2018
09:55Surface Renewal: An Advanced Micrometeorological Method for Measuring and Processing Field-Scale Energy Flux Density Data
Published on: December 12, 2013
Related Concept Videos
Multiple Regression
Farmers can use multiple regression to determine the crop yield based on more than one factor, such as water availability, fertilizer, soil properties, etc. Here, the crop yield is the response or dependent variable as it depends on the other independent variables. The analysis requires the construction of a scatter plot...
Regression Analysis
In regression analysis, a regression equation is determined based on the line of best fit– a line that best fits the data points plotted in a graph. This line is also called the regression line. The algebraic equation for the regression line is called the regression equation. It is represented as:
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Calibration Curves: Correlation Coefficient