Related Experiment Video
Updated: Dec 15, 2025

Functional Characterization and Visualization of Esophageal Fibroblasts Using Organoid Co-Cultures
Published on: January 6, 2023
Flip Technology for Assessing Esophageal Structural and Motor Disorders: a Skeptic's View
1Division of Gastroenterology & Hepatology, Medical College of Wisconsin, Hub for Collaborative Medicine, 8701 W. Watertown Plank Rd, Milwaukee, WI, 53226, USA. bmassey@mcw.edu.
Purpose Of Review:
Functional lumen impedance (FLIP) technology has become commercially available to assess structural and motor abnormalities of the esophagus. Increasing numbers of papers have described novel findings with this technology. This review examines the validity of the FLIP technique, how it compares with existing diagnostic modalities, and evidence to date on diagnostic accuracy.
Recent Findings:
FLIP studies require deep sedation at the time of endoscopy to complete. They assess a simulated state of esophageal obstruction in only a distal part of the esophagus rather than deglutitive motor function of the entire esophagus. The available normative dataset is small and not matched to the older age of patients typically being evaluated. The test-retest agreement in health and disease is unknown, as is the operator dependence on performing and interpreting findings. Studies to date have largely excluded patients with structural disorders, which FLIP cannot reliably distinguish from motor disorders. FLIP is an expensive technology that has been made clinically available without its true utility being established. For FLIP to be deemed a device ready for widespread clinical use, additional studies on validity, diagnostic accuracy, and outcomes need to be performed. Prospective clinical studies need to include all patients and assess the incremental cost-effectiveness of FLIP over more innovative use of existing technology, such as high-resolution manometry with provocative challenges.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...
Esophageal Strictures-I: Introduction
Etiology
The primary cause of esophageal strictures is long-standing gastroesophageal reflux disease (GERD), accounting for about 70 to 80% of adult cases. Chronic acid reflux can lead to injury and scarring of the esophageal lining, culminating in...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Esophagus
The movement of edibles from the pharynx into the esophagus is facilitated by the upper esophageal sphincter, which is formed primarily by the...