Related Experiment Video
Updated: Jul 26, 2026

One-step Metabolomics: Carbohydrates, Organic and Amino Acids Quantified in a Single Procedure
Published on: June 25, 2010
Analytical performance specifications based on the state-of-the-art for the newborn screening
Leonor Guiñón1, Anna Soler2, Angel Molina3
1Quality Department. Biomedical Diagnostic Center. Hospital Clínic of Barcelona; Quality Department. Laboratories. Hospital de la Santa Creu i Sant Pau of Barcelona; Biochemistry Department. Hospital de la Santa Creu i Sant Pau of Barcelona.
Newborn screening (NBS) laboratories can now use state-of-the-art total error analytical performance specifications (TE APS) to set quality standards. These TE APS, derived from EQA data, address the lack of existing Milan consensus models for NBS measurands.
Area of Science:
- Clinical Chemistry
- Biochemistry
- Public Health
Background:
- Analytical performance specifications (APS) are currently unavailable for newborn screening (NBS) measurands based on the Milan consensus models.
- There is a need for robust APS to ensure the quality of NBS testing.
Purpose of the Study:
- To establish total error (TE) APS for NBS measurands using state-of-the-art (SOTA) data.
- To provide a benchmark for analytical performance in NBS laboratories.
Main Methods:
- Utilized 23,662 results from the Spanish NBS External Quality Assessment (EQA) scheme (May 2015-September 2018).
- Calculated TE APS as the 90th percentile of measurement errors, focusing on the best 75% of results per laboratory.
- Analyzed 17 common NBS measurands, including TSH, IRT, and various acylcarnitines.
Main Results:
- TE APS varied among measurands when all methods were considered; TSH, IRT, C16, and C18 demonstrated the best performance, while Phe, C5DC, and C10 showed the poorest.
- Analytical performance generally improved (TE APS decreased) when focusing on majority methods.
- Higher TE APS were observed at lower analyte concentrations, indicating concentration-dependent performance.
Conclusions:
- The proposed TE APS, based on SOTA, offer a practical solution for NBS laboratories in the absence of Milan consensus-based APS.
- These specifications can aid NBS laboratories in establishing and maintaining high-quality testing standards.
- The findings highlight the importance of considering method and concentration when evaluating NBS analytical performance.