Fetal Umbilical Arterial Pulsatility Correlates With 2-Year Growth and Neurodevelopmental Outcomes in Congenital

Jayani B Abeysekera1, Dora L Gyenes1, Joseph Atallah2

  • 1Fetal & Neonatal Cardiology Program, University of Alberta, Edmonton, Alberta, Canada; Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada.

Insights

In fetal transposition of the great arteries (d-TGA) and hypoplastic left heart syndrome (HLHS), elevated umbilical artery pulsatility index (UA-PI) in the third trimester is linked to poorer 2-year growth and neurodevelopmental outcomes. Middle cerebral artery pulsatility index (MCA-PI) did not show a significant correlation.

Area of Science:

  • Perinatal medicine
  • Pediatric cardiology
  • Neurodevelopmental pediatrics

Background:

  • Congenital heart disease (CHD) poses risks for long-term neurodevelopmental issues in children, potentially due to prenatal factors.
  • Placental pathology and brain-sparing effects (altered fetal middle cerebral artery flow) are observed in fetuses with CHD.
  • This study examines the link between fetal arterial flow patterns and neurodevelopmental outcomes in specific CHD types.

Purpose of the Study:

  • To investigate the association between umbilical artery (UA) and middle cerebral artery (MCA) pulsatility indices (PIs) in fetuses with d-TGA and HLHS.
  • To determine the relationship between these flow patterns and growth and neurodevelopmental outcomes at 2 years of age.

Main Methods:

  • Retrospective analysis of third-trimester fetal echocardiograms in children with d-TGA and HLHS (2004-2014).
  • Measurement of UA and MCA pulsatility indices (PIs).
  • Assessment of 2-year growth (head circumference z-score) and neurodevelopmental outcomes (Bayley III scores).

Main Results:

  • In multivariate analysis, higher UA-PI was significantly associated with reduced length, weight, and cognitive scores at 2 years.
  • No statistically significant correlation was found between MCA-PI and the measured growth or neurodevelopmental outcomes.
  • Children with d-TGA and HLHS showed specific growth and neurodevelopmental score ranges at 2-year follow-up.

Conclusions:

  • Elevated third-trimester UA-PI, indicative of placental insufficiency, is associated with adverse 2-year growth and neurodevelopmental outcomes in fetal d-TGA and HLHS.
  • MCA-PI was not found to be a significant predictor of these outcomes in this cohort.
  • UA-PI may serve as a potential marker for monitoring fetal well-being and predicting neurodevelopmental trajectories in CHD.
Abstract