Related Experiment Video
Updated: Dec 15, 2025

Setup and Execution of the Rapid Cycle Deliberate Practice Death Notification Curriculum
Published on: August 5, 2020
Development and validation of an instrument for procedure-related death notification
1Department of Anaesthesia and Perioperative Medicine, Faculty of Health Sciences, University of Cape Town, South Africa. franceskateorr@gmail.com.
A revised anaesthetic death notification form was developed to improve the audit of perioperative mortality. The validated instrument enhances data collection for epidemiological, forensic, and academic purposes.
Area of Science:
- Medical Science
- Anaesthesiology
- Forensic Pathology
Background:
- Anaesthesia-related mortality is a significant cause of preventable perioperative deaths.
- The current South African Procedure-Related Death Notification (PRDN) instrument (GW7/24 form) is outdated and requires revision.
- PRDN instruments are crucial for auditing practice, medicolegal investigations, and litigation.
Purpose of the Study:
- To develop and validate a revised anaesthetic section for the South African PRDN instrument.
- To create an updated form for future use in procedure-related deaths.
- To provide a template for revising the existing GW7/24 form for various uses.
Main Methods:
- Utilized Lynn's two-stage model, starting with an extensive literature review.
- Developed a provisional instrument, reviewed by 6 local anaesthetic and forensic pathology experts.
- Rated a revised instrument by 8 national experts using a Likert scale and calculated the Content Validity Index (CVI).
Main Results:
- The provisional instrument had 14 domains and 66 items; the revised had 13 domains and 65 items.
- Three items with a CVI <0.88 were removed.
- The final instrument comprised 18 domains and 79 items, achieving an overall CVI of 1, with all items deemed relevant.
Conclusions:
- A comprehensive, updated, and validated anaesthetic section for the SA PRDN instrument has been successfully developed.
- This new instrument can serve as a government and anaesthesiology society-endorsed template.
- The validated instrument will improve the accuracy and utility of procedure-related death notifications.
More Related Videos
06:55Inverse Probability of Treatment Weighting Propensity Score using the Military Health System Data Repository and National Death Index
Published on: January 8, 2020
07:34Modified Annexin V/Propidium Iodide Apoptosis Assay For Accurate Assessment of Cell Death
Published on: April 24, 2011
Related Concept Videos
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation