Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
Hypertension assessment based on feature extraction using a photoplethysmography signal and its derivatives
1Institute of Medicine and Health, Guangdong Academy of Sciences, Guangzhou 510500, People's Republic of China.
Abstract:
Objective.Long-term abnormal blood pressure (BP) can lead to various cardiovascular diseases; therefore, it is significant to assess BP status as a preventative measure. In this study, a feature-extraction-based approach is proposed and performed on an open clinical trial dataset.Approach.Firstly, a complete ensemble of empirical mode decomposition with an adaptive noise algorithm and wavelet threshold analysis is applied to eliminate the noise interference from an original photoplethysmography (PPG) signal compared to other signal filters. Considering the strong connection between hypertension and diabetes, an analysis of variance test with a 95% confidence interval is firstly carried out to select these leading extracted morphological features, which are uniquely related to hypertension, from the PPG signal and its derivatives. Subsequently a variety of classification models are evaluated at different BP levels and their performances are compared.Main results and Significance.The test results demonstrate that the support vector machine classification model achieves a greater performance compared to other explored models in this paper, with accuracy of 78%, 87% and 88% for cases including normal versus prehypertension subjects, normotension versus hypertension subjects and non-hypertension versus hypertension subjects, respectively, which further illustrates the great potential of the proposed method in hypertension assessment.
Related Concept Videos
Hypertension III: Clinical Manifestations and Diagnostic Studies
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Hypertension I: Introduction