Measurement of optical reflection and temperature changes after blood occlusion using a wearable device
Jian Gu1, Yoko Tomioka2, Koichi Kida1
1Department of Electrical Engineering and Information Systems, Graduate School of Engineering, The University of Tokyo, Tokyo, Japan.
Abstract:
Early detection of compromised circulation is essential for postoperative monitoring of free flap. Hourly clinical check-ups such as inspection and palpation still result in a delay in detection. Conversely, optical reflection and temperature measurement are useful alternatives for detecting blood circulation. However, conventional methods that verify ischemia and congestion within a short period have not been reported. In this study, we measured short-term changes in optical reflection and temperature in a rat flap using a wearable flexible sensor probe previously developed in our laboratory. Five ischemia and five congestion groin flap models were measured using a sensor probe and reference devices. Curve fitting was performed on transition signals to evaluate changes in signals and their time constants. The optical reflection signal decreased after venous ligation and increased after arterial ligation. The parameters of the fitted curves indicate a significant difference between congestion and ischemia at p < 0.01 (probability value), which was detected within a few minutes after ligation. However, insufficient significance was observed in the temperature signal. Our method gives supporting information to verify ischemia and congestion, and has the potential to rapidly detect compromised circulation.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...